EasyManua.ls Logo

Linde T 16 - Checking the Condition and Fastening of Electrical Cables and Connections; Cleaning the Electrical Panel; Cleaning and Checking Contacts for Wear

Linde T 16
53 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3
6
0
8
0
4
2
5
1
1
-
0
5
0
4
ATTENTION
Before commencing any work on the electrical
equipment, the battery connector must be
disconnected.
Electrical system: checking the condition
and fastening of electrical cables and con-
nections
-
Re
mo
ve
th
e f
ron
t c
ov
er.
-
Check
the t
ightnes
s of
the
connecti
ons,
and e
nsure
that
there are no traces of corrosion.
-
Chec
k tha
t cab
le f
ast
enin
gs ar
e sec
ure.
-
Chec
k the cab
les fo
r any are
as of ch
afi
ng. En
sure t
hat
they are properly insulated and fastened.
NOTE
Corroded connections and damaged cables may cause
voltage drops and overheating, which can result in
malfunction.
Maintenance
Maintenance every 500 hours
Cleaning the electrical panel
- Disconnect the battery connector.
- Remove the front cover.
- Clean the pulse control panel using compressed air.
NOTE
Protect the electrical panel against moisture. Adjustment
and repair must be carried out only by our representatives
.
ATTENTION
Before commencing work on any electrical
component, disconnect the battery connector.
Cleaning and checking contacts for wear
-
Disc
onn
ect
the
bat
tery
conn
ecto
r.
-
Clea
n the con
tact
s using co
mpr
esse
d air, an
d check
their mechanical integrity.
-
Any co
nta
cts whi
ch sho
w advan
ced we
ar or subs
tan
tia
l
traces of burning must be replaced.
Always replace the contacts as a complete set.
NOTE
We recommend leaving this operation to your local
representative.