LinRS Interface
L
i
n
M
o
t
13.5Start MC- and Application SW with immediate Response
Request: Start MC- and Application SW with immediate Response
Byte
Offset
Value Description
0 01h Fix ID telegram start
1 11h MACID
2 03h Data length
3 02h Fix ID start data
4 05h Sub ID: Start MC- and application SW with immediate
response
5 06h Main ID: Program Handling Message Group
6 04h Fix ID telegram end
Response: Start MC- and Application SW with immediate Response
The drive answers with the configured default response.
Example:
Tx: 01 11 03 02 05 06 04
Rx: 01 11 0C 02 00 00 00 F6 40 00 00 8A 00 00 00 04
The default response is given immediate, to detect restart completion poll the drive until it
answers.
NTI AG / LinMot User Manual LinRS Interface / 03/10/2017 Page 47/59