30
Reassembling the Meter
Reassembling the Weldment Assembly
12. Install a new O-Ring in the groove around the
weldment base assembly if required.
13. Position the weldment cover on top of the weldment
base so that the cover vent plug is on top.
Install the screws around the rim of the weldment
cover. Attach the nuts to the back of each screw.
Begin by hand-tightening each of the screws. Once
this is complete, tighten the nuts and bolts to the
proper torque following the tightening sequence on
Page 31.
14. To complete the reassembly, reinstall the adjuster
and drive components. When this is complete,
reinstall the dust cover.