8-26 CHAPTER 8: OPERATION
ALPHA ST320 S2
MODE 29
:
::
:
Synchronization signal (A6, optional) setup 2 of 2 (refer to MODE 13 for
related setup)
Defines if the synchronization device (Y03) is activated or not.
The following conditions must be fulfilled to allow is activation.
• Swiss type lathe
• MODE 13=1
• Chuck closed
0 - Synchronization signal (a6) is activated when the bar
feeder in Synchro mode is.
1 - Synchronization signal (a6) is deactivated when the bar
feeder in Synchro mode is.
Modify the following modes according to the lathe provided
signals:
conditions
Provided signal Mode setup
A2 A6 Mode 3 Mode 29
1 yes yes 0 0
2 yes No 0 1
3 No yes 1 0
4 No no 1 1
MODE 30
:
::
:
Lathe door sensor signal (A7, optional) logic setup
Allows to control the pusher speed in manual mode when the
lathe door is open.
0 – The lathe signal (A7) is activated when the door is open.
.
1 – The lathe signal (A7) is deactivated when the door is open.
If the lathe does not provides A7, MODE 30=0
MODE 31
:
::
:
Length check skip
Define the number of check processes for the feeding length
that will be skipped after a new bar stock was loaded.
Possible values are 1 to 5.