CHAPTER 8: OPERATION 8-17
ALPHA ST320 S2
7. SERVICES PARAMETERS
Service parameters must only be modified by technicians of or personnel authorized by LNS. Incorrect
setup might cause unexpected malfunction or damage on either bar feed system or lathe. Accessing
these parameters is password protected. Please contact LNS or its official agent in your country for
getting technical support in case any modification is needed.
7.1. Accessing
After selecting the operation parameters, the following screen will be displayed:
MODE 1
:
::
:
Simulation
When this MODE is ON, the bar feed system runs feeding and
bar change cycles automatically and not controlled by either
interface signals or manual operation.
This MODE is for factory test or exhibition purpose only.
When it’s connected with the lathe, it must always be turned
OFF.
0 - Turn SIMULATION OFF
1 - Turn SIMULATION ON
Press F0 to edit the
parameter value.
Press PgUp/PgDn
to display the
parameters
Press ENTER to
validate the
change.
Press F4 to return to
previous page
Press F1 to access service
parameters.