8-20 CHAPTER 8: OPERATION
ALPHA ST320 S2
MODE 10
Lathe type setup 1 of 3 (refer to MODE 21, 22 for related setup)
0 – The lathe is fixed type.
1 – The lathe is Swiss type.
MODE 11
Feeder status check
This parameter checks if the bar feed system is in
AUTOMATIC mode when the chuck signal is turned ON/OFF
for 3 cycles. If not, the bar feed system activates the alarm
e11.
0 – Deactivate this check.
1 – Activate this check.
MODE 12
Bar change setup 3 of 3 (refer to MODE 7 and 19 for further information)
Defines pusher action between chuck open and the next bar
feed system action when BAR END signal is currently arising.
0 The pusher keep pushing forward. VERIFIER SI
INVERSER
1 – The pusher terminates pushing force.
MODE 13
Synchronization device (optional) setup 1 of 2 (refer to MODE 29 for related
setup)
0 – Activate synchronization device.
1 – Deactivate synchronization device.