EasyManua.ls Logo

LNS Alpha ST320 S2 - Page 99

LNS Alpha ST320 S2
138 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CHAPTER 8: OPERATION 8-21
ALPHA ST320 S2
MODE 14
Bar end signal (R3) setting
Defines the timing to activate BAR END signal.
0 BAR END signal is calculated according to P02 “Part
length” and P04 “Bar end position”
1 BAR END signal is given according to P04 bar end
position”
MODE 15
PLC output setup (R2) 1 of 2 (refer to MODE 16 for further information)
0 Y05 is ON when a new bar stock arrives at TOP CUT
position.
This signal is called START signal.
1 – Y05 acts according to MODE 16 setup.
MODE 16
PLC output contact Y05 setup 2 of 2 (refer to MODE 15 for further
information)
This parameter is only available when MODE 15 is set 1.
0 – Y05 is ON
- When a new bar stock arrives at TOP CUT position.
- After every feeding.
Signals sent under this condition are called CYCLE
START signal.
1 Y05 starts to be ON when a new bar stock arrives at TOP
CUT position and OFF when the next loading cycle
initiated.
Signal sent under this condition is called WORKING
signal.