CHAPTER 8: OPERATION 8-21
ALPHA ST320 S2
MODE 14
:
::
:
Bar end signal (R3) setting
Defines the timing to activate BAR END signal.
0 – BAR END signal is calculated according to P02 “Part
length” and P04 “Bar end position”
1 – BAR END signal is given according to P04 “bar end
position”
MODE 15
:
::
:
PLC output setup (R2) 1 of 2 (refer to MODE 16 for further information)
0 – Y05 is ON when a new bar stock arrives at TOP CUT
position.
This signal is called START signal.
1 – Y05 acts according to MODE 16 setup.
MODE 16
:
::
:
PLC output contact Y05 setup 2 of 2 (refer to MODE 15 for further
information)
This parameter is only available when MODE 15 is set 1.
0 – Y05 is ON
- When a new bar stock arrives at TOP CUT position.
- After every feeding.
Signals sent under this condition are called CYCLE
START signal.
1 – Y05 starts to be ON when a new bar stock arrives at TOP
CUT position and OFF when the next loading cycle
initiated.
Signal sent under this condition is called WORKING
signal.