UTRID-16 Factory Presets
LogTag
®
UTRID-16 recorders can be client configured using LogTag
®
Analyzer. For an out-of-box solution they can also be ordered in volume, pre-
configured with a factory profile, ready for starting.
If a default configuration does not suit, customers can compile their own profile by specifying the parameters in the tables below when ordering.
Please note that minimum order quantities apply for UTRID-16 recorders with profiles not stocked by LogTag
®
Recorders .
Description Default Profile Range/Option Your requirement
Profile Name
Standard Options
UserID - ASCII text up to 38 characters
1
-
Start method Push button start Push button start Push button start
Record pre-start readings enabled enabled or disabled
Number of readings to record 8,000 1-16,129
Sampling interval 5 minutes 1 minute to 18 hours
Start Delay 60 minutes 1 minute to 72 hours, 0=no delay
Configure requires password disabled enabled or disabled
Download requires password disabled enabled or disabled
Password - Up to 6 ASCII characters
Advanced File Options
Generate PDF file enabled enabled or disabled
Generate LTD file enabled enabled or disabled
Generate CSV file disabled enabled or disabled
Temperature units °C °C or °F
Time Zone UTC +0:00 -12:00 to +14:00 in 15min steps
Time format 24-hour 24-hour or 12 hour (am/pm)
Date format DD/MM/YY DD/MM/YY or MM/DD/YY
Calculate MKT enabled enabled or disabled
Activation Energy default default or custom value (please specify)
PDF Options
Generate Data List enabled enabled or disabled
Y-Axis scaling
Range range of readings range of readings, range of sensor or custom
Custom upper
2
- -25°C to 6C (-13°F to 140°F)
Custom lower - -25°C to 6C (-13°F to 140°F)
Show Y-axis grid lines enabled enabled or disabled
Show X-axis grid lines enabled enabled or disabled
Show upper alarm line disabled enabled or disabled
Show lower alarm line disabled enabled or disabled
Allow stopping with STOP/Review button
enabled enabled or disabled
Prioritise download over file generation disabled enabled or disabled
1
All units associated with a profile must have the same UserID. The text cannot be individually customised per unit. The text cannot contain characters from an extended character set
such as Chinese or Cyrillic
2
Upper value must be above lower value
Page 18 of 21 UTRID-16 Product User Guide, Revision 1, copyright © 2004-2016, LogTag
®