37
Checking Accumulation
Description of Status Word of Response:
= 0xaa, Successful;
= 0x55, Failed.
6.4.3.3.27. Lo-lo Limit Value Setting
Request:Master Response:Slaver
Domain name Data(hex) Domain name Data(hex)
Beginning code 7E Beginning code 7E
Address 01-63 Address 01-63
Function code 37 Function code 37
Length of data 4 Length of data 1
Lo-lo limit value
(
MMSB
)
Status of response
Lo-lo limit value(MSB)
Checking Accumulation
Lo-lo limit value(LSB)
Lo-lo limit lag value
Checking Accumulation
Description of Status Word of Response:
= 0xaa, Successful;
= 0x55, Failed.
6.4.3.3.28. Calibration Parameters Setting
Request:Master Response:Slaver
Domain name
Data
(
hex
)
Domain name
Data
(
hex
)
Beginning code
7E
Beginning code
7E
Address 01-63 Address 01-63
Function code 38 Function code 38
Length of data 5 Length of data 1
Capacity(MMSB) Status of response
Capacity(MSB)
Checking Accumulation
Capacity
(
LSB
)
Decimal point
Scale division
Checking Accumulation
Description of Status Word of Response:
= 0xaa, Successful;