7.4. Parameter List of Calibration in Kind
Table 7-2
CAL1
Name
Position
of decimal
point
0-4
0:No decimal place 12345
2:2 decimal places 123.45
3:3 decimal places 12.345
4:4 decimal places 1.2345
The minimum weighing division can
be any one of 1、2、5、10、20、50.
The maximum range of weighing;
This setting value +9d(9 个分度)
can be displayed.
While the weight exceeds the above
value, it can not be displayed.
The voltage that is input from the load
calibration. The unit is mV.
In the calibration in kind, the voltage
input from the load cell is decided in
the capacity calibration.
It is the difference between weighing
point and zero point. The unit is mV.
7.5. Parameter List of Digital Calibration
Table 7-3
Position
of decimal point
0-4
0:No decimal place 12345
4:4 decimal places 1.2345
The minimum weighing division
can be any one of 1、2、5、10、
20、50.
weighing;
This setting value +9d(9 个分
度)can be displayed.