AllowOineTxForUnknownId: If set to yes, an unknown ID (not in Authorization and Cache List)
will be accepted and start the charging session when Loop EV-Flex EVSE is not connected to
central system.
AuthorizationCacheEnabled: Loop EV-Flex EVSE supports an Authorization Cache or not.
AuthorizeRemoteTxRequests: Whether a remote request to start a transaction in the form of a
RemoteStartTransaction.req message should be authorized beforehand like a local action to start a transaction.
BlinkRepeat: Number of times to blink the Loop EV-Flex EVSE lighting when signaling. This value is not changeable.
ClockAlignedDataInterval: Size (in seconds) of the clock-aligned data interval. This is the size (in seconds) of the set
of evenly spaced aggregation intervals per day, starting at 00:00:00 (midnight).
ConnectionTimeOut: Interval until incipient charging session is automatically canceled due to failure of EV user to
insert the charging cable connector(s) into the appropriate connector(s).
GetCongurationMaxKeys: Maximum number of requested conguration keys in a GetConguration.req PDU.
HeartBeatInterval – Denes the heartbeat interval.
LightIntensity: Percentage of maximum intensity at which to illuminate the Loop EV-Flex EVSE lighting.
LocalAuthorizeOine: Whether the Loop EV-Flex EVSE, when oine, will start a transaction for locally-
authorizedidentiers.
LocalPreAuthorize: Whether the Loop EV-Flex EVSE, when online, will start a transaction for locally authorized
identiers without waiting for or requesting an Authorize.conf from Central System.
MaxEnergyOnInvalidId: Maximum energy in Watt-hour (Wh) delivered when an identier is invalidated by Central
System after start of a transaction.
MeterValuesAlignedData: Clock-aligned measurand(s) to be included in a MeterValues.req PDU, every
ClockAlignedDataInterval seconds. Supported value are Current.Import, Energy.Active.Import.Register, and
Temperature, Voltage or any combination of these 4 value.
MeterValuesAlignedDataMaxLength: Maximum number of items in a MeterValuesAlignedData
conguration key.
MeterValuesSampledData: Sampled measurands to be included in a MeterValues.req PDU, every
MeterValueSampleInterval seconds. Supported value are Current.Import, Energy.Active.Import.Register, and
Temperature, Voltage or any combination of these 4 value.
MeterValuesSampledDataMaxLength: Maximum number of items in a MeterValuesSampledData
conguration key.
MeterValueSampleInterval: Interval between sampling of metering (or other) data, intended to be transmitted by
“MeterValues” PDUs
MinimumStatusDuration: The minimum duration that a Loop EV-Flex EVSE or connector status is stable before a
StatusNotication.req PDU is sent to Central System.
NumberOfConnectors: The number of physical charging connectors of this Loop EV-Flex EVSE.
ResetRetries: Number of times to retry an unsuccessful reset of the Loop EV-Flex EVSE.
ConnectorPhaseRotation: The value will always be ‘NotApplicable’.
38
Loop EV-Flex
TM
EVSE
EVS-32A-L2-001 (R-Model)
v.20.9.4
www.evLoop.io