4.3. Charging an Electric Vehicle (EV)
Choices of start charging are as below:
4.3.A. Plug and Charge
1. Insert the charging plug into the EV
2. Charging session started
Figure 21 Connect the charging plug to the EV
4.3.B. RFID Card
1.) Insert the charging plug into the EV
2.) Swipe card
3.) Waiting for authorizing
4.) Charging session started
4.4 Stop Charging
1. Unplug any time (disconnect the charging plug from EV to stop charging session)
2. Session ended (please return the connector to the holster)
4.4.A. Interrupt Charging
Please refer to STOP CHARGING section for more information.
4.4.B. Auto Restart
When a charging session is interrupted due to a temporary error condition, the Loop EV-Flex EVSE will automatically
restart charging when the cause of the temporary error condition returns to normal. Status indicator lights remain
ashing RED until the error condition is resolved.
+ Temporary error conditions include: Over Current, Over Voltage, Under Voltage, and Over Temperature.
+ For Over Current conditions: The charging session will be stop while OC occurs. After recovery from OC for 30
seconds, the Loop EV-Flex EVSE will automatically restart charging for three times.
+ When charging session stopped due to CCID trip, the Loop EV-Flex EVSE will try to restart after 15 minutes for 3
times.
60
Loop EV-Flex
TM
EVSE
EVS-32A-L2-001 (R-Model)
v.20.9.4
www.evLoop.io