StopTransactionOnInvalidId: Whether the Loop EV-Flex EVSE will stop an ongoing transaction whe
it receives a non-accepted authorization status in a StartTransaction.conf for this transaction.
StopTxnAlignedData: Clock-aligned periodic measurand(s) to be included in the TransactionData element of
StopTransaction.req MeterValues.req PDU for every ClockAlignedDataInterval of the charging session.
Supported value are Current.Import, Energy.Active.Import.Register, and Temperature, Voltage or any combination of
these 4 value.
StopTxnAlignedDataMaxLength: Maximum number of items in a StopTxnAlignedData conguration key.
StopTxnSampledData: Sampled measurands to be included in the TransactionData element of StopTransaction.req
PDU, every MeterValueSampleInterval seconds from the start of the charging session. Supported value are Current.
Import, Energy.Active.Import.Register, and Temperature, Voltage or any combination of these 4 value.
StopTxnSampledDataMaxLength: Maximum number of items in a StopTxnSampledData conguration key.
SupportedFeatureProles: A list of supported Feature Proles. Possible prole identiers: Core,
FirmwareManagement, LocalAuthListManagement, Reservation, SmartCharging and RemoteTrigger.
SupportedFeatureProlesMaxLength: Maximum number of items in a SupportedFeatureProles conguration key.
TransactionMessageAttempts: How often the Loop EV-Flex EVSE should try to submit a transaction-related
message when Central System fails to process it.
TransactionMessageRetryInterval: How long the Loop EV-Flex EVSE should wait before resubmitting a transaction-
related message that Central System failed to process.
UnlockConnectorOnEVSideDisconnect: When set to true, the Loop EV-Flex EVSE SHALL unlock the cable on the
EVSE side when the cable is unplugged at the EV. Fixed value.
WebSocket Ping Interval: Dene the ping pong interval for WebSocket protocol.
LocalAuthListEnabled: Whether the Local Authorization List is enabled.
LocalAuthListMaxLength: Maximum number of identications that can be stored in the Local Authorization List.
SendLocalListMaxLength: Maximum number of identications that can be send in a single SendLocalList.req.
ReserveConnectorZeroSupported – If this conguration key is present and set to true: The Loop EV-Flex EVSE
support reservations on connector 0.
ChargeProleMaxStackLevel: Max Stack Level of a Charging Prole. The number dened also indicates the max
allowed number of installed charging schedules per Charging Prole purposes.
ChargingScheduleAllowedChargingRateUnit: A list of supported quantities for use in a Charging Schedule. This value
will always be ‘Current’.
ChargingScheduleMaxPeriods: Maximum number of periods that may be dened per Charging Schedule.
ConnectorSwitch3to1PhaseSupported: If dened and true, this Loop EV-Flex EVSE supports switching from 3 to 1
phase during a charging session. This is currently not supported by the Loop EV-Flex EVSE.
MaxChargingProlesInstalled: Maximum number of charging proles installed at a time.