Chapter 6 Instruction Details
XBC E-Type Main Unit 6-98 Ve r. 1
6.19.8 RMOV, RMOVP, LMOV, LMOVP
Instruction
Area Available
Step
Flag
P M K F L T C S Z D.x
R.x
Co
nst.
U N D R
Error
(F110)
Zero
(F111)
Carry
(F112)
RMOV(P)
LMOV(P)
S
O
O
O
O
O
O
O
-
O
-
-
O
O
O
O
O
2~5 O - -
D
O
O
O
-
O
O
O
-
O
-
-
-
O
O
O
O
Operand
Description
Data Type
S
Data to transfer or device number data is saved in
REAL/LREAL
D
Device number to save data transferred
REAL/LREAL
1) RMOV( Real Move)
(1) It transfers S+1,S device’s Real Data to D+1,D.
(2) If input a constant in S, decimal input type can be input. Hexadecimal input type is not permitted.
2) LMOV (Long Real Move)
(1) It transfers S+3,S+2,S+1,S’s Long Real Data to (D+3,D+2,D+1,D).
(2) If input a constant in S, decimal input type can be input. Hexadecimal input type is not permitted.
3) Program Example
(1) If input contact point P00000 is On, Long Real data 1.234 is saved in D1000 by Long Real data.
RMOV 1.234 D1000
P00000
RMOV, LMOV
means RMOV/LMOV
S
D
P
S
D
RMOVP, LMOVP

Table of Contents

Related product manuals