Chapter 7 Built-in High-speed Counter Function
XBC E-Type Main Unit 7-26 Ver. 1
7.2.2 Error code
1. Error occurred is saved in the following area.
Category
Remark
2. Error codes and descriptions
Error code
Description
Counter type is set out of range
Pulse input type is set out of range
22
Requesting #1(3,)channel Run during the operation of #0(2) channel 2 phase(
* During #0(2) channel 2 phase inputting, using #1(3)channel is not possible.
Compared output type setting is set out of range.
Internal preset value is set out of counter range
External present value is set out of counter range
27
Ring counter setting is set out of range
* Note ring counter setting should be 2 and more.
Compared output min. value is set out of permissible max. input range
Compared output max. value is set out of permissible max. input range
Error of Compared output min. value>Compared output max. value
Compared output is set out of the default output value
Set value of Unit time is out of the range
Pulse value per 1 revolution is set out of range
▪ If two or more errors occur, the module saves the latter error code and removes
the former one.