Chapter 8 Option Boards and Memory Module
XBC E-Type Main Unit 8-30 Ver. 1
c. If you click “OK” button”, it reads each parameter from the memory module.
Note
- “Open from memory module” and “Write to Memory module” menus of PADT are activated
when PLC is Offline. They are deactivated when PLC is Online.
- When connecting with PADT, connection type should be ‘USB’
8.10.4 How to use when password is set
1. When connecting PADT with memory module
a. When setting password during programming and writing program to memory module, it
is saved according to rotary switch operating mode without functions cancelling the
password
i. When writing program, check whether to use password at ‘Write’ window.