Chapter 6 Instruction Details
XBC E-Type Main Unit 6-276 Ve r. 1
2) Program Example
VZONE D00011
300 50
D00021
P00011
If D00010 is -500, D00040 = -650
If D00010 is -400, D00040 = -550
If D00010 is -200, D00040 = -350
If D00010 is -100, D00040 = -200
If D00010 is 0 , D00040 = 0
If D00010 is 100, D00040 = 200
If D00010 is 200, D00040 = 350
If D00010 is 400, D00040 = 550
If D00010 is 500, D00040 = 650
Output
Input
Reciprocal of
inclination 50