Do you have a question about the Lumel RE72 and is the answer not in the manual?
| Input Voltage | 230 V AC |
|---|---|
| Output Type | Relay |
| Number of Outputs | 2 |
| Display | LED |
| Housing | Plastic |
| Switching Current | 8 A |
| Control Algorithm | PID |
| Protection Level | IP20 |
| Mounting Type | Panel mounting |
| Output Relay | 2 relays |
Procedure for fixing the controller in the panel using screw clamps.
Details on connecting input signals and outputs using terminal strips.
Instructions on how to modify the set point value using push-buttons.
Guide to accessing and modifying controller parameters via the programming matrix.
Diagram illustrating the navigation and structure of the programming matrix.
Detailed steps for changing numerical and text parameter settings.
List of configuration parameters with descriptions and available ranges.
Details on configuring the universal main input for sensors and signals.
Instructions for setting up the additional input for remote set points or retransmission.
Description of available functions for binary inputs.
Information on configuring controller outputs and pulse period recommendations.
Explanation of the ON-OFF control method with hysteresis for temperature control.
Details on the advanced PID algorithm for accurate temperature control.
Description of the step-by-step control algorithm for cylinder control.
Explanation of the Gain Scheduling function for objects with varying behavior.
Configuration for heating-cooling control loops using PID parameters.
Overview of available alarm types and how to configure them for each output.
Explanation of timer activation, status display, and alarm indication.
Instructions for connecting and measuring current using a current transformer.
How to monitor heating, cooling, or valve signals via the controller display.
Procedure for entering and operating the manual control mode.
Configuration for retransmitting selected values to external recorders.
Limitation of temperature accretion rate for smooth set point changes.
Enabling and configuring a low-pass filter to stabilize measured values.
Procedure to restore the controller to its default factory settings.
Table detailing parameters for programming control and their ranges.
Guide to creating and configuring up to 15 set point value programs.
Instructions for starting and controlling programs, including locking mechanisms.
Overview of the RE72 controller's serial interface and Modbus protocol functions.
List and explanation of error codes encountered during Modbus communication.
Table detailing the organization and description of Modbus register groups.
Steps for updating the controller's firmware using PC software.
Table of character messages, reasons, and procedures for error handling.
Table specifying sensor types and their corresponding input ranges.
Explanation of how controller versions are coded based on features and options.
Information on controller maintenance, guarantee period, and repair policy.