17. TECHNICAL DATA
Main input
Input signals and measuring ranges Table 19
1)
The intrinsic error is related to measuring range 200…1767 °C
(392...3212,6 °F)
Sensor type Standard Range
Sym-
bol
Pt100 EN
60751+A2:1997
-200...850 °C -328...1562 °F
pt1
Pt1000 -200...850 °C -328...1562 °F
pt10
Fe-CuNi (J)
EN 60584-
1:1997
-100...1200 °C -148...2192 °F
t-,
Cu-CuNi (T) -100...400 °C -148...752 °F
t-t
NiCr-NiAl (K) -100...1372 °C -148...2501,6 °F
t-k
PtRh10-Pt (S) 0...1767 °C 32...3212,6 °F
t-s
PtRh13-Pt (R) 0...1767 °C 32...3212,6 °F
t-r
PtRh30-PtRh6 (B)
0...1767 °C
1)
32...3212,6 °F
1)
t-b
NiCr-CuNi (E) -100...1000 °C -148...1832 °F
t-e
NiCrSi-NiSi (N) -100...1300 °C -148...2372 °F
t-n
Chromel – Kopel (L) GOST R 8.585-
2001
-100...800 °C -148...1472 °F
t-l
linear, current (I) 0...20 mA 0...20 mA
0-20
linear, current (I) 4...20 mA 4...20 mA
4-20
linear, voltage (U) 0...5 V 0...5 V
0-5
linear, voltage(U) 0...10 V 0...10 V
0-10