EasyManuals Logo

Lumel RE72 User Manual

Lumel RE72
96 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #87 background imageLoading...
Page #87 background image
87
87
17. TECHNICAL DATA
Main input
Input signals and measuring ranges Table 19
1)
The intrinsic error is related to measuring range 200…1767 °C
(392...3212,6 °F)
Sensor type Standard Range
Sym-
bol
Pt100 EN
60751+A2:1997
-200...850 °C -328...1562 °F
pt1
Pt1000 -200...850 °C -328...1562 °F
pt10
Fe-CuNi (J)
EN 60584-
1:1997
-100...1200 °C -148...2192 °F
t-,
Cu-CuNi (T) -100...400 °C -148...752 °F
t-t
NiCr-NiAl (K) -100...1372 °C -148...2501,6 °F
t-k
PtRh10-Pt (S) 0...1767 °C 32...3212,6 °F
t-s
PtRh13-Pt (R) 0...1767 °C 32...3212,6 °F
t-r
PtRh30-PtRh6 (B)
0...1767 °C
1)
32...3212,6 °F
1)
t-b
NiCr-CuNi (E) -100...1000 °C -148...1832 °F
t-e
NiCrSi-NiSi (N) -100...1300 °C -148...2372 °F
t-n
Chromel – Kopel (L) GOST R 8.585-
2001
-100...800 °C -148...1472 °F
t-l
linear, current (I) 0...20 mA 0...20 mA
0-20
linear, current (I) 4...20 mA 4...20 mA
4-20
linear, voltage (U) 0...5 V 0...5 V
0-5
linear, voltage(U) 0...10 V 0...10 V
0-10

Other manuals for Lumel RE72

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lumel RE72 and is the answer not in the manual?

Lumel RE72 Specifications

General IconGeneral
BrandLumel
ModelRE72
CategoryController
LanguageEnglish