Magellan 15
14 = Bypass programming 01 to 32 = User number
99 = Any user number
15 = User code activated output 01 to 32 = User number
99 = Any user number
16 = Wireless smoke maintenance signal 01 to 32 = Zone number
99 = Any zone number
17 = Delay zone alarm transmission 01 to 32 = Zone number
99 = Any zone number
18 = Zone signal strength weak 1 01 to 32 = Zone number
99 = Any zone number
19 = Zone signal strength weak 2 01 to 32 = Zone number
99 = Any zone number
20 = Zone signal strength weak 3 01 to 32 = Zone number
99 = Any zone number
21 = Zone signal strength weak 4 01 to 32 = Zone number
99 = Any zone number
22 = Reserved
23 = Reserved
24 = delay started 01 to 32 = Zone number
99 = Any zone number
25 = Fire delay cancelled 01 to 32 = Zone number
99 = Any zone number
26 = User remote access granted 01 to 32 = User number
99 = Any user number
27 = Bus module event 00 = A bus module was added
01 = A bus module was removed
29 = Arming with user 01 to 32 = User number
99 = Any user number
30 = Special arming 00 = Auto-arming (on time/no movement)
01 = Late to close
02 = No movement arming
03 = Partial arming
04 = Quick arming
05 = Arming through WinLoad
99 = Any special arming
31 = Disarming with user 01 to 32 = User number
99 = Any user number
32 = Disarming after alarm with user 01 to 32 = User number
99 = Any user number
33 = Alarm cancelled with user 01 to 32 = User number
99 = Any user number
34 = Special disarming 00 = Auto-arm cancelled (on time/no movement)
01 = Disarming through WinLoad
02 = Disarming through WinLoad after alarm
03 = Alarm cancelled through WinLoad
04 = Paramedical alarm cancelled
99 = Any special disarming
35 = Zone bypassed 01 to 32 = Zone number
99 = Any zone number
36 = Zone in alarm 01 to 32 = Zone number
99 = Any zone number
37 = Fire alarm 01 to 32 = Zone number
99 = Any zone number
38 = Zone alarm restore 01 to 32 = Zone number
99 = Any zone number
Event Group # Sub-group #

Table of Contents

Other manuals for Magellan MG5000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Magellan MG5000 and is the answer not in the manual?

Magellan MG5000 Specifications

General IconGeneral
BrandMagellan
ModelMG5000
CategoryControl Panel
LanguageEnglish