EasyManuals Logo

Magellan MG5000 Programming Guide

Magellan MG5000
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #16 background imageLoading...
Page #16 background image
16 Programming Guide
39 = Fire alarm restore 01 to 32 = Zone number
99 = Any zone number
40 = Special alarm 00 = Panic non-medical emergency
01 = Panic medical (this panic alarm is not UL approved)
02 = Panic fire
03 = Recent closing
04 = Global shutdown
05 = Duress alarm
06 = Keypad lockout
99 = Any special alarm event
41 = Zone shutdown 01 to 32 = Zone number
99 = Any zone number
42 = Zone tampered 01 to 32 = Zone number
99 = Any zone number
43 = Zone tamper restore 01 to 32 = Zone number
99 = Any zone number
44 = New trouble 00 = TLM trouble (Partition 1 only)
01 = AC failure (Partition 1 only)
02 = Battery failure (Partition 1 only)
03 = Auxiliary current overload (Partition 1 only)
04 = Bell current overload (Partition 1 only)
05 = Bell disconnected (Partition 1 only)
06 = Clock loss (Partition 1 only)
07 = Fire loop trouble (Partition 1 only)
08 = Fail to communicate to monitoring station telephone #1
(Partition 1 only)
09 = Fail to communicate to monitoring station telephone #2
(Partition 1 only)
10 = Fail to communicate to pager report (Partition 1 only)
11 = Fail to communicate to voice report (Partition 1 only)
12 = RF interference (Partition 1 only)
99 = Any new trouble event
45 = Trouble restored 00 = Telephone line restored (Partition 1 only)
01 = AC failure restore (Partition 1 only)
02 = Battery failure restore (Partition 1 only)
03 = Auxiliary current overload restore (Partition 1 only)
04 = Bell current overload restore (Partition 1 only)
05 = Bell disconnected restore (Partition 1 only)
06 = Clock loss restore (Partition 1 only)
07 = Fire loop trouble restore (Partition 1 only)
12 = RF interference restore (Partition 1 only)
99 = Any trouble restored event
46 = Bus module new trouble 00 = Bus communication fault (Partition 1 only)
01 = Tamper trouble (Partition 1 only)
99 = Any bus module new trouble event
47 = Bus module trouble restored 00 = Bus communication fault restore (Partition 1 only)
01 = Tamper trouble restore (Partition 1 only)
99 = Any bus module trouble restored event
48 = Special 00 = System power up
01 = Reporting test
02 = WinLoad log on
03 = WinLoad log off
04 = Installer in programming mode
05 = Installer exited programming mode
06 = Maintenance in programming mode
07 = Maintenance exited programming mode
08 = Closing delinquency delay elapsed
99 = Any special event
Event Group # Sub-group #