MG6250 • Section Programming Guide
Version 1.6
System Programming | 29
Wireless Repeater Trouble/Restore Report Codes
Wireless Siren Trouble/Restore Report Codes
Wireless Remote Trouble/Restore Report Codes
System Programming
General Options
Section Description Data Section Description Data
[1737]
Wireless repeater supervision loss /
[1738]
Wireless repeater supervision loss restore /
Wireless repeater battery trouble / Wireless repeater battery trouble restore /
Wireless repeater AC trouble / Wireless repeater AC trouble restore /
Future use - Future use -
Default = FF
Section Description Data Section Description Data
[1739]
Wireless siren tamper trouble /
[1740]
Wireless siren tamper trouble restore /
Wireless siren supervision loss / Wireless siren supervision loss restore /
Wireless siren battery trouble / Wireless siren battery trouble restore /
Wireless siren AC trouble / Wireless siren AC trouble restore /
Default = FF
Section Description Data
[1741]
Wireless remote battery trouble /
Wireless remote battery trouble restore /
Future use -
Future use -
Default = FF
Section
Option Description
OFF ON
[2000]
1 Access code length 6 Digits 4 Digits
2 Audible trouble warning (except AC power failure) Disabled Enabled
3 AC power failure warning Disabled Enabled
4Lock master code Disabled Enabled
5 Console tamper supervision Disabled Enabled
6 Code necessary to bypass zones Disabled Enabled
7 Partition One Two
8 Future use --
Section
Option Description
OFF ON
[2001]
1Panic 1 (Emergency) Disabled Enabled
2 Panic 2 (Auxiliary) Disabled Enabled
3 Panic 3 (Fire) Disabled Enabled
4Panic 1: Report only or audible alarm Report only Audible
5Panic 2: Report only or audible alarm Report only Audible
6Panic 3: Report only or audible alarm Report only Audible
7 Future use --
8Auto-Time Adjust Disabled Enabled