Version 1.6
52 | Appendix A: EN 50131 Programming
MG6250 • Section Programming Guide
Appendix A: EN 50131 Programming
The following sections describe all the programming required for your console to be EN 50131 compliant.
IMPORTANT: To set your panel to be EN 50131 compliant, enter section [9003].
The following sections and options (in bold) are those that are new or need to be modified for EN 50131 compliancy.
System Timers
General Options “A”
General Options “C”
Arming/Disarming Options
Section Description Data (value from 000 to 255) Default Setting
[2020] Entry delay 1 ____/____/____ seconds 045 sec.
- ---
[2042] EN50131 fail to communicate timer ____/____/____ seconds 120 sec.
[2043] Keypad Lockout ____/____/____ attempts 5 attempts
[2044] Keypad Lockout Duration ____/____/____ minutes 15 minutes
[2048] Trouble Shutdown ____/____/____ times 5 times
[2049] Panic Shutdown ____/____/____ times 10 times
Section
Option Description
OFF ON
[2000]
1 Access code length 6 Digits 4 Digits
2 Audible trouble warning (except AC power failure) Disabled Enabled
3 AC power failure warning Disabled Enabled
4 Lock master code Disabled Enabled
5 Console tamper supervision Disabled Enabled
6 Code necessary to bypass zones Disabled Enabled
7 Partition Disabled Enabled
8 Future use --
Section
Option Description
OFF ON
[2002]
1 Volume boost on entry/exit Disabled Enabled
2 Volume boost in speaker phone mode Disabled Enabled
3 Check-in supervision time 24 Hrs. 80 minutes
4 RF jamming supervision Disabled Enabled
5Daylight savings time Disabled Enable
6Trouble latch Disabled Enabled
7 Need code to view troubles/events Disabled Enabled
8 Bell squawk when installer enters programming Disabled Enabled
Section
Option Description
OFF ON
[2003]
1 Bell squawk when arming/disarming with remote control Disabled Enabled
2 Stay arming switches to Force Stay arming Disabled Enabled
3 Sleep arming switches to Force Sleep arming Disabled Enabled
4 Full arming switches to Force Full arming Disabled Enabled
5 Report system disarming Always
After alarm
only
6 One-touch Stay arming Disabled Enabled
7 One-touch Sleep arming Disabled Enabled
8 One-touch Full arming Disabled Enabled