Section Description Data (value from 000 to 255) Default Setting
[2020] Entry delay 1 ____/____/____ seconds 045 sec.
[2021] Entry delay 2 ____/____/____ seconds 045 sec.
[2022] Intellizone delay ____/____/____ seconds (minimum 10 seconds) 045 sec.
[2023] Recent closing delay ____/____/____ seconds Disabled
[2024] Auto-zone shutdown counter ____/____/____ times 005 times
[2025] Remote lock delay ____/____/____ seconds 020 sec.
[2026] Delinquency delay ____/____/____ days Disabled
[2027] Power failure report delay ____/____/____ minutes 015 min.
[2028] Pre-alarm delay (StayD) ____/____/____ seconds 015 sec.
[2029] Re-arm delay (StayD) ____/____/____ seconds 005 sec.
[2030] Entry delay audio selection ____/____/____ (000 to 006*)005
[2031] Exit delay audio selection ____/____/____ (000 to 006*)002
[2032] Number of rings ____/____/____ rings 008 rings
[2033] Answering machine override delay ____/____/____ seconds 030 sec.
[2034] TLM fail timer ____/____/____ seconds 032 sec.
[2035] Delay alarm transmission ____/____/____ seconds Disabled
[2036] Delay between dialling attempts ____/____/____ seconds (maximum 130 seconds) 020 sec.
[2037] Lowest rate (primary communication) ____/____ (01=landline; 02 = GSM) Disabled
[2038] Auto-test report ____/____/____ days Disabled
[2039] Auto-test report time ____/____:____/____ Disabled
[2040] GSM network failure delay ____/____/____ seconds 032 sec.
[2041] GPRS bandwidth saver delay ____/____/____ minutes Disabled
[2042] EN50131 fail to communicate timer ____/____/____ seconds 0
[2043] Keypad lockout ____/____/____ attempts 0 attempts
[2044] Keypad lockout duration ____/____/____ minutes Report only
[2048] Trouble shutdown ____/____/____ times 0
[2049] Panic shutdown ____/____/____ times 0
* 000 = No tone; 001 = Beeping; 002 = Countdown; 003 = Tonality 1; 004 = Tonality 2; 005 = Tonality 3; 006 = Tonality 4
Table 9: Country codes for the MG6250
Input Value Country Input Value Country
00 Mexico; St. Johns; Bahamas; Turks and Caicos 10 Chatham
01 Cuba 11 Tonga
02 Brazil 12 Iraq; Syria
03 Chile 13 Israel
04 Falkland Islands 14 Lebanon; Kyrgyzstan
05 Paraguay 15 Palestine
06 European Union; United Kingdom; Greenland 16 Egypt
07 Russia and surrounding countries 17 Namibia
08
South Australia; Victoria; Australian Capital Territory; New
South Wales
18 Canada; United States
09 Tasmania; Lord Howe Island 19 New Zealand
Section Description Data
[2045] Country code ___/___ value from 00 to 99