MG6250 • Section Programming Guide
Version 1.6
Partition Programming | 33
Partition Programming
Partition Options
Partition Delays
Partition Auto-Arm Time
Area Label
Section
Option Description
OFF ON
[2101]
Area 1
1 & 2
Auto-arm on time
1 2
Disabled OFF OFF
Stay arm ON OFF
Sleep arm OFF ON
Full arm ON ON
3 & 4
Auto-arm no movement
3 4
Disabled OFF OFF
Stay arm ON OFF
Sleep arm OFF ON
Full arm ON ON
5 Switch to Stay arming if no entry delay zone is opened Disabled Enabled
6 Follow zones become Entry Delay 2 zones when Delay Zone is bypassed Disabled Enabled
7 No exit delay when arming with remote control Disabled Enabled
8 Exit delay termination Disabled Enabled
[2102]
Area 2
1 & 2
Auto-arm on time
1 2
Disabled OFF OFF
Stay arm ON OFF
Sleep arm OFF ON
Full arm ON ON
3 & 4
Auto-arm no movement
3 4
Disabled OFF OFF
Stay arm ON OFF
Sleep arm OFF ON
Full arm ON ON
5 Switch to Stay arming if no entry delay zone is opened Disabled Enabled
6 Follow zones become Entry Delay 2 zones when Delay Zone is bypassed Disabled Enabled
7 No exit delay when arming with remote control Disabled Enabled
8 Exit delay termination Disabled Enabled
Section Partition 1 Range Delay Default Setting
[2110] Exit delay 000 to 255 sec. / / 060 sec.
[2111] Bell cut-off delay 000 to 255 min. / / 004 min.
[2112] No movement delay 000 to 255 x 15 min. / / 000 min.
Section Partition 2 Range Delay Default Setting
[2120] Exit delay 000 to 255 sec. / / 060 sec.
[2121] Bell cut-off delay 000 to 255 min. / / 004 min.
[2122] No movement delay 000 to 255 x 15 min. / / 000 min.
Section Partition Auto-arm Time
[2151] Partition 1 auto-arm time / : /
[2152] Partition 2 auto-arm time / : /
Section Area Area Label
[2161] 1 / / / / / / / / / / / / / / /
[2162] 2 / / / / / / / / / / / / / / /