38 | Description of MG6250 Events
MG6250 • Section Programming Guide
45 Special disarming
00 Auto-arm cancelled (on-time/no movement)
1, 2, 3
01 Disarming through BabyWare
02 Disarming through BabyWare after alarm
03 Alarm cancelled via BabyWare
04 Paramedic alarm cancelled
05 Disarm with keyswitch
06 Disarm with keyswitch after an alarm
07 Alarm cancelled with keyswitch
46 Zone bypassed
01 - 64 Zone number
1, 2, 3
99 Any zone number
47 Zone in alarm
01 - 64 Zone number
1, 2, 3
99 Any zone number
48 Fire alarm
01 - 64 Zone number
1, 2, 3
99 Any zone number
49 Zone alarm restore
01 - 64 Zone number
1, 2, 3
99 Any zone number
50 Fire alarm restore
01 - 64 Zone number
1, 2, 3
99 Any zone number
51 Zone shutdown
01 - 64 Zone number
1, 2, 3
99 Any zone number
52 Special alarm
00 Panic emergency 1, 2, 3
01 Panic medical 1, 2, 3
02 Panic fire 1, 2, 3
03 Recent closing 1, 2, 3
04 Global shutdown 1, 2, 3
05 Duress alarm 1, 2, 3
06 Keypad lockout
53 Paramedic alarm
01 - 16 User number
1, 2, 3
99 Any user number
54 Special
00 System power up
1
01 Reporting test
02 Software log on
03 Software log out
04 Installer in programming mode
05 Installer exited programming mode
06 Closing delinquency delay elapsed
07 Fail to arm
55 New trouble
00 Telephone line trouble
1
01 AC failure
02 Battery failure
03 Timer loss trouble
04 Console tamper
05 RF jamming
06 GSM no service
07 GSM supervision loss
08 IP no service
09 IP supervision loss
10 IP receiver lost
11 Fail to communicate to central
12 Fail to communicate personal reporting
Table 12: Reportable Events/Saved Events (continued)
Event Event Description Sub-event Sub-event Description Area

Table of Contents

Related product manuals