5 Programming
18 MAGNETEK HPV1000 AC Elevator Drive Technical Manual
Table 2 S-Curves A2 Submenu
A2 Parameter Name Description
Units Default
Accel Rate 0 Acceleration Rate Limit
m/s
2
0.80
Decel Rate 0 Deceleration Rate Limit
m/s
2
0.80
Accel Jerk In 0
Rate of increase of acceleration, up to ACCEL RATE, when
increasing elevator speed
m/s
3
0.60
Accel Jerk Out 0
Rate of decrease of acceleration to zero when approaching contract
elevator speed
m/s
3
0.60
Decel Jerk In 0
Rate of increase of deceleration, up to DECEL RATE, when
decreasing elevator speed
m/s
3
0.60
Decel Jerk Out 0
Rate of decrease of deceleration to zero when slowing the elevator to
zero or level speed
m/s
3
0.60
Accel Rate 1 Acceleration Rate Limit
m/s
2
0.80
Decel Rate 1 Deceleration Rate Limit
m/s
2
0.80
Accel Jerk In 1
Rate of increase of acceleration, up to ACCEL RATE, when
increasing elevator speed
m/s
3
0.60
Accel Jerk Out 1
Rate of decrease of acceleration to zero when approaching contract
elevator speed
m/s
3
0.60
Decel Jerk In 1
Rate of increase of deceleration, up to DECEL RATE, when
decreasing elevator speed
m/s
3
0.60
Decel Jerk Out 1
Rate of decrease of deceleration to zero when slowing the elevator to
zero or level speed
m/s
3
0.60
Accel Rate 2 Acceleration Rate Limit
m/s
2
0.80
Decel Rate 2 Deceleration Rate Limit
m/s
2
0.80
Accel Jerk In 2
Rate of increase of acceleration, up to ACCEL RATE, when
increasing elevator speed
m/s
3
0.60
Accel Jerk Out 2
Rate of decrease of acceleration to zero when approaching contract
elevator speed
m/s
3
0.60
Decel Jerk In 2
Rate of increase of deceleration, up to DECEL RATE, when
decreasing elevator speed
m/s
3
0.60
Decel Jerk Out 2
Rate of decrease of deceleration to zero when slowing the elevator to
zero or level speed
m/s
3
0.60
Accel Rate 3 Acceleration Rate Limit
m/s
2
0.80
Decel Rate 3 Deceleration Rate Limit
m/s
2
0.80
Accel Jerk In 3
Rate of increase of acceleration, up to ACCEL RATE, when
increasing elevator speed
m/s
3
0.60
Accel Jerk Out 3
Rate of decrease of acceleration to zero when approaching contract
elevator speed
m/s
3
0.60
Decel Jerk In 3
Rate of increase of deceleration, up to DECEL RATE, when
decreasing elevator speed
m/s
3
0.60
Decel Jerk Out 3
Rate of decrease of deceleration to zero when slowing the elevator to
zero or level speed
m/s
3
0.60
Fast Stop Time Used when a Fast Stop is invoked.
m/s
2
2.0