Engineered XLTX Transmitter Instruction Manual
December 2016
Page 24 of 49
To cancel the IR configuration receiver without a successful link, move the OFF-ON-Start toggle
to the OFF position.
4.1.4 RCP IR Configuration on Transmitters without a Display
4.1.4.1 Transmitters Equipped with Separate Power/Status and Battery LED Indicators
The RCP IR Configuration feature (supported in common code version 6.2 and greater) allows
the transmitter configuration to be read and written through the IR Adapter port. Contact customer
service to determine if your transmitter is compatible. You will also need to have an IR Adapter
available to configure the device.
To utilize the RCP IR configuration feature on compatible transmitters:
1. Push the OFF-ONSTART toggle to the START position and hold for more than 5
seconds.
o When the transmitter successfully enters the IR configuration mode, the
Power/Status and Battery LED(s) will blink alternately continuously.
2. After the LEDs are blinking alternately, point the IR adapter at the IR window of the
transmitter and use RCP to send and receive data.
NOTE: This is the same procedure to enter in to IR Configuration Pairing with a receiver. The
difference is that to pair a transmitter with a receiver you have to press the OFF-ON START
toggle. To communicate with RCP you do not have to press Start (this will place you into a
different mode). The device is sitting ready to communicate while the LEDs are blinking. For
transmitters with the display please reference Section 4.2.2.9.
4.1.4.2 IR Configuration Receiver on Transmitters Equipped with Single Status/Battery
LED Indicator
To utilize the IR configuration receiver function and link to a compatible receiver, push the OFF-
ON-Start toggle to the Start position and hold for more than 5 seconds. When the transmitter
successfully enters the IR configuration mode, the Status/Battery LED will blink continuously.
After the LED is blinking, point the IR window of the transmitter at the desired receiver to control
and momentarily press the OFF-ON-Start toggle to the Start position and release.
If the link is successful, the LED will stop blinking and the transmitter will shut down. The new
settings obtained from the IR configuration function will take effect upon the next power cycle of
the transmitter.
If the link is unsuccessful with a compatible receiver, the Status/Battery LED will continue to blink.
To cancel the IR configuration receiver without a successful link, move the OFF-ON-Start toggle
to the OFF position.
4.2 USING THE TRANSMITTER IN SETUP MODE (WITH GRAPHIC INTERFACE)
The Setup Mode can be used to edit configuration settings such as: Access Code, Channel
Select, User Code, Transmitter Time Out, Backlight Time Out, Password Enable, Change
Password, and more.
NOTE: No parameter changes will take effect until the user has selected ‘Save and Exit’ from the
Setup Mode.
4.2.1 Entering Setup Mode
To enter the Setup Mode, first make sure the unit is OFF and the Machine Stop switch is raised.
Next, push the OFF-ON-START toggle switch to the START position and hold it in the START
position for more than 5 seconds until the setup screen appears.