ENGINEELECTRICS
Removingthechargeairpressure
sensor
Disconnectingtheelectricalconnection
•Disconnecttheelectricalconnection(1)
Removingthepressuresensor
•Unscrewandremovethemountingbolts(1)
•Pulloutthepressuresensor(2)
Installingthechargeairpressuresensor
Installingthepressuresensor
•Insertthepressuresensor(2)withanewO-ring
•Screwinthemountingbolts(1)andtightenthem
to9Nm
Connectingtheelectricalconnection
•Connecttheelectricalconnection(1)
34AE63stedition