3 - 14
1
1
2
2
1
1
CHECK Alternator/crankshaft belt tension
t
IMPORTANT
t
If the belt is changed, check the tension again after the first20 hours of service.
- Open the engine cover.
- Check the belt for signs of wear and cracks, and change if necessary (eFILTER
ELEMENTS AND BELTS).
- Check the belt tension between the fan pulley and the alternator
pulley(22,03lbs/98N). The clearance should be about0,3 to 0,4 in (7to9 mm).
- Adjust if necessary.
- Loosen screws1 by two to three thread turns.
- Swivel the alternator assembly so as to obtain the required belt tension.
- Retighten screws1 (tightening torque16ft-lbs ±1,6ft-lbs 22N.m ±2,2N.m).
CHECK Tyre pressures
CHECK Wheel nut tightening
t
IMPORTANT
t
Check that the air hose is correctly connected to the tyre valve before inflating and keep all persons at a distance during inflation. Follow the recommended tyre pressures.
- Check the condition of the tyres, to detect cuts, blisters, wear, etc.
- Check the wheel nut tightening. Non-compliance with this instruction can lead to deterioration and breakage of the
wheel bolts and distortion of the wheels.
- Check and restore tyre pressures if necessary (e2-DESCRIPTION: TYRES).
NOTE: There is an OPTIONAL wheel tool kit.
CHECK Transfer box oil level
Place the lift truck on level ground with the engine stopped.
- Visually check for any traces of seepage or leakage from the various filler, level
and drain plugs.
- If there is any leakage or seepage, check the level.
- Remove the level plug1, the oil should be flush with the edge of the hole.
- If necessary, add oil (
eLUBRICANTS AND FUEL) by the same hole.
- Refit and tighten the level plug1 (tightening torque25-36 ft-lbs34-49 N.m).
Ü
50H-WEEKLY SERVICE OR EVERY50 HOURS OF SERVICE
CHECK Compressor belt tension (Air conditioning option)
t
IMPORTANT
t
If the belt is changed, check the tension again after the first20 hours of service.
- Open the engine cover.
- Check the belt for signs of wear and cracks, and change if necessary (eFILTER
ELEMENTS AND BELTS).
- Check the belt tension between the pulleys of the crankshaft and the compressor
- Under a normal pressure exerted with the thumb(10lbs/45 N), the clearance
should be approximately 0,39 in (10 mm).
- Adjust if necessary.
- Loosen the screws1 and nuts2 by two to three thread turns.
- Swivel the compressor assembly so as to obtain the belt tension required.
- Re-tighten screws1 and nuts2 (tightening torque16ft-lbs ±1,6ft-lbs 22N.m
±2,2N.m).