Normal Tare
To enter Tare
1
Place a tray (the tare weight) on the platform, and press the
TARE key .
2 The NET indicator lights up to show that a tare is in use, and
the Weight Display shows zero.
3 Subsequently, the NET weight on the platform is shown on
the Weight Display.
If tare is used, check the tare from time to time:
♦ Place a tray on the platform, and notice if the Weight Display returns
to zero. If not, tare the scale again by pressing the
TARE key .
To remove Tare
1
Empty the platform.
2 Press the TARE key .
The Net indicator is turned off.
Direct sale to the public
Note: In some market areas the scale’s tare function may be protected with
a software switch.
9
This changes the way you work with tare:
• you must remove tare (see above) before you can set a new tare value
that is lower than the current tare value.
• preset tare cannot be used.
Automatic Tare
To use automatic Tare
1
Turn application switch
on (see “The APP Command”
on page 34).
2 Place a tray (the tare weight) on the platform, and press the
TARE key (normal tare, see above).
Use whichever weighing method that suits you to weigh or
grade the contents of the tray.
3 Remove the tray, and place a new tray on the platform.
4 If the second tray is within ± 10% of the first tray, the weight
of this tray will be automatically tared and the Weight
Display will show zero.
Note: The Automatic Tare function can compensate for up to 10% or
30% variation in the tare. The limit is selected during the configuration of
9
According to standard regulations on conditions for direct sale to the public.