the scale. The second tray you put on an empty platform will be tared
automatically if it is within ± 10% of the weight set by the manual tare
operation. For this function to work it is important that the scale is stable
and with an empty platform before you place the second tray on the scale.
Preset Tare
10
To use preset Tare
1 Select a memory by using the arrow keys and .
2 Press the MENU key for a few seconds.
3 Select the
command with the arrow keys.
4 Press PRINT . The memory’s current weight limits are
displayed on the Weight Display.
5 Press PRINT again. The first digit on the display starts to
flash, indicating that it can be changed to a new value.
6 Use the UP/DOWN arrows to change the value for the weight
limit digits. Press
PRINT to activate each digit.
Note: You must activate all digits (press PRINT six
times) or no change will take place.
7 Press the MENU key to return to Edit Mode where you
can select one of the other edit commands.
8 Press the MENU key a second time to return to Operating
Mode.
Zero
To take a new operational zero point
1
Remove any weight from the platform.
2 Press the ZERO key .
The Zero indicator lights up.
Tip
• If the
ZERO key does not function, you may have to take
a new initial zero by turning the power off and then on again,
or by pressing the
arrow, the MENU and ZERO
keys simultaneously. (See “Zero Key” on page 13 for more
details on the Zero function.)
10
In order to use Preset Tare, the S12 software switch must be set to ON.
20 • Basic Operation M1100, U2 & C2-3.3