90-13645--2 4952B-14 ELECTRICAL AND IGNITION
3 Cylinder Battery Charging Diagram
with Battery Isolator (Small Voltage
Regulator)
IMPORTANT: After electrical connections are
made, coat all terminal connections using Quick-
silver Liquid Neoprene (92-25711), to avoid corro-
sion.
51051
BLK
GRY
Large Red
(Output) Lead
RED
RED
RED
RED
B1
B2
RED
A
Small
Red
(Sense)Lead
BLK
YEL
YEL
BLK
YEL
YEL
GRY
GRY
YEL
YEL
RED
RED
BLK BLACK
BLU BLUE
GRY GRAY
RED RED
YEL YELLOW
a
b
c
d
e
f
g
h
i
j
a - Stator
b - Terminal Block
c - To Tachometer
d - Voltage Regulator/Rectifier
e - Battery Isolator
f - Auxiliary Battery
g - Start Battery
h - To Remote Control Harness
i - 20 Ampere Fuse
j - Starter Solenoid

Table of Contents