12
3. Profiles
3.5. AdJUSt description and use
The individual proles and their activation parameters are xed in the process of manufacture. Some users may prefer a higher activation
altitude, which gives them more time to deal with an emergency in case of activation. In some countries or at some dropzones a higher
activation altitude may be required by local regulations. The AdJUSt function allows the user to modify the current prole and increase the
activation altitude in case this is considered necessary. In the current prole the Top activation altitude may be increased in several steps, A1
to A9. The individual increments are approx. 30 m / 100 ft. The maximum increase in the activation altitude is approx. +270 m / 900 ft. The
AdJUSt setting is permanent and is displayed together with the current prole on the control unit display.
Warning:
- The altitude lock increases adequately according to the selected step A1 to A9! (Section 7.2.)
- Take care to open the main parachute in time as you may quickly reach the activation altitude!
Procedure of setting the AdJUSt function can be found in Section 6.3.