28
6. SEtUP
6.3. AdJUSt setting description
The setting is performed when switching on the device. Briey press the yellow button on the control unit, GO-ON sign appears (for 2 seconds).
Do not hold the button, depress it only briey!!! During the time the GO-ON sign is displayed, immediately after it comes on, depress the
yellow button briey once again. The GO-ON sign appears again. After the yellow button is depressed again (GO-ON sign displayed), the last
preset PROFILE can be seen on the display (Stu, Int, Pro, Cpi, Tan). Do not press the button to conrm the prole, but wait for the OFFSEt sign
to appear, after two seconds the INFO sign appears and after another two seconds the SETUP comes on - conrm by depressing the button
shortly.
SCALE is shown as rst, do not conrm, afterwards the ProFilE comes on, do not conrm. Wait until AdJUSt is displayed, than conrm it by
shortly pressing the button. By conrming access to the ADJUSt menu, the individual increases in activation altitude A1 to A9 begin to show
in two-second intervals.
Conrm the displayed altitude A by pressing the button. The selected prole and increased activation altitude A1 to A9 are set when the m
2
multi device is switched on again.
Meters/feet are added to the activation altitude of the set prole as follows:
A1 approx. + 30m / 100ft
A2 approx. + 60m / 200ft
A3 approx. + 90m / 300ft
A4 approx. +120m / 400ft
A5 approx. +150m / 500ft
A6 approx. +180m / 600ft
A7 approx. +210m / 700ft
A8 approx. +240m / 800ft
A9 approx. +270m / 900ft
Warning:
ADJUSt changes the altitude lock of the selected prole by the set value A1 - A9