SILENT 12
21
I
GB
3.2.2 Rotor diodes
Characteristics : 3F diodes bridge
Test method:
-To disconnect the extremities of the 6 diodes
-Check with a tester with the (+) prod on A and
the (–) prod on K if there is continuity.
-Check that when inverting the tester prods there
is no continuity.
N.B. Every plate, (Fig.10, rif.2) is equal to the
other and 2 diodes of opposite polarity are in-
serted you
REMEDY: Replace the faulty diode.
3.2.3 Varistor
Characteristics : V 420 LA20
Test method:
-Disconnect the rheophores and check that
there is no continuity (Fig.10, rif.3).
RIMEDIO: Replace the faulty varistor
3.2.2 Ponte diodi rotante
Caratteristiche : ponte diodi 3F
Metodo di controllo:
-Scollegare le estremità dei 6 diodi
-Verificate con un tester con il puntale (+) su A e
(–) su K ci sia continuità.
-Verificate che invertendo i puntali del tester non
ci sia continuità.
N.B.Ogni placca (Fig.10, rif.2), è uguale all'altra
e vi sono inseriti 2 diodi di polarità opposta
RIMEDIO: Sostituire il diodo difettoso e
resinarlo abbondantemente.
3.2.3 Varistore
Caratteristiche : V 420 LA20
Metodo di controllo:
-Scollegare i reofori e verificare che non ci sia
continuità (Fig.10, rif.3).
RIMEDIO: Sostituire il varistore difettoso e
resinarlo abbondantemente.
3 ALTERNATOR

Table of Contents