Slot Type Multi Video Signal Generator MSPG-8000
www.Ltdmaster.com 82
4.9 System option
You can set up the default setting on MSPG-8000.
Press the K/B button and press the SYSTEM OP. button.
① Buzzer On: Button touch/press buzzer on/off setting
a. Buzzer off: 0
b. Buzzer on: 1
② EDID Check Option: EDID check function
a. EDID Pass[0]: Do not check EDID
b. EDID Check[1]: EDID check
EDID normal: Normal display with sound
EDID abnormal: No display or no sound
③ Sync Level [2000~5500]: Analog Horizontal and Vertical sync level setting, default is 4800