59
clockIdentityPTPclockidentity
NumberofportsGMR1000deviceshaveoneRJ45.EventhoughGMR5000deviceshavetwoRJ45’s,they
areconsideredtobeasinglelogicalPTPport.
clockQuality.clockClassTheGMRproductlinecanhavethefollowingclockclasses.NonGMRproducts
mayhaveadditionalvalues.
6
lockedtoGPS
7previouslylockedtoGPS
13lockedtotimecode,NTP,etc.
14previouslylockedtotimecode,NTP,etc.
52outofholdoverspec.forclass7,degradationA
58outofholdoverspec.forclass14,degradationA
187
outofholdoverspec.forclass7,degradationB
193outofholdoverspec.forclass14,degradationB
248defaultifnoneoftheabove
clockQuality.clockAccuracyTheGMRproductlinecanhavethefollowingaccuracies.NonGMRproducts
mayhaveadditionalvalues.
32accurateto
25ns
33accurateto100ns
34accurateto250ns
35accurateto1us
36accurateto2.5us
37accurateto10us
38accurateto25us
39accurateto100us
40accurateto250us
41accurateto1ms
42accurateto
2.5ms
43accurateto10ms
44accurateto25ms
45accurateto100ms
46accurateto250us
47accurateto1s
48accurateto10s
49accurateto>10s
254accuracyunknown