7.2 Specifications 24V models
Max. AC input current (@ 230VAC)
Max. AC input current (@
120VAC)**
Number of battery outlets
IUoUo, automatic, 3-step+
Charge voltage Absorption*
Max absorption and max. bulk
timer*
8 hours (start max. bulk timer at 26.5V)
Maximum ripple voltage on DC
Flooded (default), GEL, AGM, Lithium-ion (MLI), Constant voltage
(26.5V)
Recommended battery capacity
Battery temperature sensor and cable included.
Yes, by means of automatic compensation or MasterShunt
–25°C (–13°F) to 80°C (176°F)
Derating 1%/°C (0,5%/°F) from 40°C (104°F) to 60°C (140°F)
Derating 8%/°C (4,4%/°F) from 60°C (140°F) to 70°C (158°F)
Communication available, 0% output power from 70°C (158°F) to
80°C (176°F)
Vario fan and natural cooling to ensure optimized cooling
Powering capabilities for
MasterBus
When the charger is switched on and AC is available, it can power
up to three non-powering devices.
Yes, conforming to SAE J1171/ISO 8846
* Adjustable, see chapter 4 for settings
** The input RCD/Fuse rating selection must be greater than 120% of the max input current (@ 120VAC)
or in accordance with the requirements of national electrical regulations.