Matrix SATATYA Devices Manual 197
Controls
The following icons appear from left to right at the bottom of the viewing area when a channel is selected by clicking
in the monitoring window.
Camera Settings Menu button shown above is available only for Analog PTZ Camera.
Start Recording:
This option enables to start the local manual recording of the selected channel. The recorded files of pre-defined
duration are stored at the path as set from the “Local Settings” of the Device Client. Click on the icon again to
stop the recording. The record files are stored at the specified path in .stm format. Now, the user cannot view this
file and so a device player is needed which converts the .stm file into avi format.
Camera Settings Menu: This option enables to open the analog PTZ camera settings menu by entering
the preset position as shown below.