7
T50/T100 PTM – User Guide – Version 2 Issue 1
Overview – Print Head Description
INK LED – Ink level indicator: lit Green when there is sufficient ink, Orange when the ink
level is detected as being low, and Red when there is no ink. Do not operate the print head
when the LED is lit red! This will cause air to be sucked in to the ink system.
READY LED – This signals whether the print head has warmed up and is ready for use.
When the print head is cold (it needs to warm up), the LED is lit Orange. When the print
head is warm it will turn Green. The warm-up time is dependent upon ambient temperatures
and takes approximately two minutes.
Labelling
The print heads’s serial plate is located on top of the Ink-Reservoir, as shown below.
Figure 4 - T50/T100 Serial plate labelling
Operating Requirements.
Before installing or operating the print head, read and adhere to all of the safety instructions
as provided under “Safety Requirements” on page 3.
The operating and power supply requirements for the T50/T100 are provided below in 2.
Strictly obey the electrical specifications provided in this manual.
Table 2 - Operating requirements (Sheet 1 of 2)
Feature Specification
Operating Temperature: 50°F – 104°F (10°C – 40°C)
Humidity Range: 10% – 90% RH (non-condensing)
Main power supply
Matthews power supply pack used:
Single phase 110 – 240 VAC, 50 – 60 Hz, 0.8 A
Direct connection:
24 VDC ± 0,5 V, 90 W, filtered DC