6 Troubleshooting
47
Diagnosis: Faults during Operation of the IMC15
Nr. Error message Meaning Diagnosis Action
112 DrIoffset Drive current off-
set
DC offset of drive
power stage out of
range
Hardware damage
IMC15
Replace IMC15
117 SCfault Short circuit fault
Defective IGBT
module
Hardware damage
IMC15
Replace IMC15
118
...
123
U15P_OV
U15P_UN
U15N_OV
U15N_UN
Uref_OV
Uref_UN
Over/ undervolt-
age MBE/processor
power supplies
Hardware damage
IMC15
Replace IMC15
Caution: The fault history is displayed on the dis-
play pages number 121, 122 and 123. Please do
not confound page numbers and fault numbers!
124
125
UZ_OV
UZ_UN
Over/ undervolt-
age DC-Bus AMB
Hardware damage
IMC15
Replace IMC15
301 AmpFlt Amplifier fault
Defective AMB
power stage or
short of bearing
magnet / cable
Hardware damage
bearing system
Check bearings and cable for shorts and ground
connections
Ok:
Replace IMC15
not Ok:
Replace bearing cable
Fault persists:
Replace blower