5 Operation
19
5.3.2 Mode 1: Main Menu
The main menu contains all functions that can be accessed using the keypad and the display.
1 Main Menu
Group Menu Item Description
11 Selfcheck Monitor 111 Selfcheck Monitor Displays selfcheck faults
12 Fault History 121 Fault History Acesses fault history (see 5.5), loads fault records from
memory
122 Fault History Displays records of the fault history (see 5.5)
123 Fault History Displays cause of fault (details of given fault record), (see
5.5)
13 System Monitor 131 Currents Displays output current of FC as percentage of maximum
current and in ampere peak (before harmonics filtering, NO
measurement of motor current)
132 Voltages Displays AMB and FC DC bus voltages
133 Forces Displays bearing forces as percentage of admissible force
(starting with SW V4.10 in transformed coordinates)
134 Displacements Displays AMB displacements as percentage of the maximum
admissible displacements
135 Temperatures Displays system temperatures
- Drive: heat sink temperature FC
- AMB: heat sink temperature AMB
- DSP: processor temperature
including the corresponding limits