6 Troubleshooting
51
904
...
908
ItFlt0 ... 4 Integrator fault 0
... 4
Static force over-
load channel 0 ... 4
Defective blower
or defective IMC15
Reset fault and restart
Fault persists:
Replace IMC15
Fault persists:
Replace blower
909 OvSpdFlt Overspeed fault
Rotational speed
out of range
Overspeed of blo-
wer of hardware
damage
Reset fault and restart
Fault persists:
Replace IMC15
Fault persists:
Replace sensor cable
Fault persists:
Replace blower
910 PlsFlt Pulse fault
Unprecise pulse
signal
Hardware damage
IMC15 or damage
blower
Reset fault and restart
Fault persists:
Replace IMC15
Fault persists:
Replace sensor cable
Fault persists:
Replace blower
Diagnosis: Faults during Operation of the IMC15
Nr. Error message Meaning Diagnosis Action