MONITOR 2.00
2-18
MONITOR – VERSION 2.00
CAL 2 Calibration
Tank 1 (fuel) Capacity
Setting
t1 = tank 1
1. Press the button until t1 is displayed. t1 = tank 1.
2. Press
once more. The word no and the fuel icon will be
displayed.
NOTE:The word “no” will not go away unless the gauge sees a tank
connected to the system. With no tank connected, you will not be able
to enter a capacity.
3. Enter the capacity of tank 1 in gallons using the
key.
4. Press the
button to save and move to the next func-
tion.
Tank 2 Capacity Setting
NOTE:Tank 2 does not have to
be a fuel tank. It could represent
an oil tank for example.
t2 = tank 2
1. Press the button until t2 is displayed. t2 = tank 2.
2. Press
once more. The word no and the fuel icon will be
displayed.
3. Enter the capacity of tank 2 in gallons using the
key.
NOTE:The word “no” will not go away unless the gauge sees a tank
connected to the system. With no tank connected, you will not be able
to enter a capacity.
4. Press the
button to save and move to the next func-
tion.