Installers manual 10.03.02-R03 (201058) EN SDA-04 (SW 5.xx) - SDA-04DCB2 (SW 22.00) Page 28 of 55
3 = Input 12 activated => Emergency open
4 = Input 12 activated => Open door or immediately close when the door is opened
5 = Input 13 activated => Press 1x - door will partially open, press 2x door will fully
open (buttons should be pressed in quick succession)
Parameter 87 : Assigned to inputs 15 and 16, fixed value
Parameter 88 : (0) Interlock: temporary change of interlock status
(input 23) An external contact can be used to temporarily disable the interlock function
if the interlock is active.
0 = Serves as an input for feedback from an external lock
1 = Serves as an input for an external (N.C.) “stop” switch in case of activated motor
frost protection (Parameter 37=1, standard “stop” input (input 6) can’t be used).
Input 23 acts as input 6 normally would.
2 = Input is configured to act as a “permanent toggle” input (fully open/close).
In case of an opened door, activation of inputs 12,13,15 or 16 can alter the door
state. On activation of either inputs 1 “Lock” or 2 “One-Way” the door will close.
3 = Input is configured to act as a “permanent toggle” input (fully open/close).
In case of an opened door, activation of inputs 12,13,15 or 16 CAN NOT alter the
door state. On activation of either inputs 1 “Lock” or 2 “One-Way” the door WILL
NOT close.
4 = Cancels the interlock, the door remains closed during Timer 1 or for as long as the
contact is closed (contact time > Timer 1)
5 = Cancels the interlock, the door opens during Timer 1 or for as long as the contact is
closed (contact time > Timer 1) Activating inputs 12, 13, 15 or 16 will close the door.
The interlock function remains deactivated until the end of the timer countdown
(local operation continues to be possible)
6 = Cancels the interlock, the door remains closed during Timer 2 or for as long as the
contact is closed (contact time > Timer 2)
7 = Cancels the interlock, the door opens during Timer 2 or for as long as the contact is
closed (contact time > Timer 2) Activating inputs 12, 13, 15 or 16 will close the door.
The interlock function remains deactivated until the end of the timer countdown
(local operation continues to be possible)