Installers manual 10.03.02-R03 (201058) EN SDA-04 (SW 5.xx) - SDA-04DCB2 (SW 22.00) Page 38 of 55
11.2 Priorities
De SDA-04 controller heeft verschillende ingang en menu instellingen waarmee de invloedd van signalen
uit de omgeving en het gedrag van de deurbewegingen bepaald kan worden. In situaties waarin deze
signalen tot conflicterend gedrag zou kunnen leiden, worden prioriteiten gebruikt om te bepalen wat de
actie van de deur zal zijn. Hiervoor zijn de volgende niveaus gedefinieerd:
Critical safety, stop immediately
Emergency stop
Hardware fault
Installation fault
Configuration fault
Menu is activated
Close in case of fire (low energy mode),
manual opening possible
Deactivate lock, in case of emergency
input, override safety at opening
Emergency input
Safety input
Open or close in case of fire, manual
opening possible
Open or close by input signals override
Open or close by manual door movement
(pull&go)
Door movements controlled by input
signals
This input is used to bring the door to the "Half
open" position or to allow the door to close in the
event of a 'Pulse open/Pulse close' system. When it
is 'one_way', the action is blocked.
This input is used to bring the door to the 100%
open position or to allow the door to close in the
event of a 'Pulse open/Pulse close' system. When it
is 'one_way', inside signals can open the door.
This input is used to bring the door to the "Half
open" position or to allow the door to close in the
event of a 'Pulse open/Pulse close' system. When it
is 'one_way', inside signals can open the door.
This is an input to which the feedback signal of a
lock can be connected.
This is the input to which the safety list can be
connected. At the same time, this input can also be
used for sliding space security.
This input can be used for the self-monitoring of
safety systems or as an input for the sliding space
protection. When this signal is activated, the door
only moves at a ´slow speed´.
The input edge_control can also be used as an input
for the sliding space security.
This input is used for the signal of the 1st safety
device.
This input is used for the signal of the 2nd safety
device.