7.3.6 Advanced Network and Interlock functionality
Parameter 90 : (0) Door number
When a door is to be connected to the Metaflex door Server (MDS) via the
optional TCP/IP interface, the door must get a unique number that is set here.
0 = No door number is set
1..255 = The number of the door
Attention:
Each door must have a unique number; if more than one door has the same
number, this will lead to conflicts in the software.
Parameter 91 : (0) Interlock: Time
0 = Normal interlock configuration (no time limit)
1..5 = In order to prevent a build-up of persons in a interlock, it is possible to
automatically override the interlock operation after a set time (seconds)
(Lock input will be ignored)
Parameter 92 : (0) Interlock: Retain the command to "open"
If the interlock is active, retains the command "open" from the “next door waiting”.
0 = Memory function disabled
1 = Memory function enabled