page: 35
Space can add between program codes as the separator, it’s also OK not to have separator.
The program must start with G92. G92 can’t be in any place except the first line..
Absolute programming is default. You can use G90/G91 to change absolute/incremental
coordinate, or use U and V to be incremental coordinate values of X and Y.
Running speed can use F code, but the value is integer instead of decimals.
The end of the program should have following code
M02 (main program ends)
When there is a problem to cut a whole circle, maybe it is caused by calculation tolerance
(code tolerance), you can change a entry point or kerf value.
11.3.2 Problems when running program
Problem: After pause, restart, there is no pierce (sometimes)
Solution: pause, restart after backward
Max. program code is 99 sections when moving pierce point backward
11.4 Controller functions declaration
If there are incorrect and undetailed contents in the manual, the standard is subject to
controller’s functions.
Functions change or upgrade without notice.
Please contact after-sale for learning functions.
The latest manual (PDF) is available.