Microstep Website http://www.microstep.cc/eng
北京欣斯达特数字科技有限公司 Beijing Flourishing Start Digital Technology Co., Ltd
page: 1
Safety notice
Please carefully read the manual before using this controller.
Safety operation
Please read the safety notice and understand how to use the controller and make necessary
safety protection measurements. Please contact us if you have other requests.
Mechanical dangerousness
Operation and repair of automation equipments are a little dangerous and are careful.
Please be far away from the working equipment. Please control the equipment by correctly
using the panel’s buttons. Don’t wear so loose clothes when using and repairing the
equipment.
High-voltage dangerousness
Be careful of electric shock during operation. Please install the equipment according to
its manual. Don’t touch cables or wires after power on. Only professional maintenance
personal can open the controller. When the equipment has problems, power should be off
and then repair.
Power isolation
Please check whether power is AC220V±15%.
AC stabilized-voltage power is a must if power is beyond the above range.
In some places there is no normal power, such as zero wire and ground wire are together
or no zero wire, an isolation transformer must be used from 2-phase/3-phase AC380V to
2-phase AC220V.
A lightning rod is also a must.
Working environment
The controllers working temperature is 0-40℃. If out of its working temperature, the
controller probably works worse. If the temperature is below 0℃, the screen will not display
normally.
Relative humidity is 0-85%.
Special protection is a must when working in high-temperature, high-humidity, and
corrosive-gas environment.
Don’t ask dusts, metal chips and others to go into the controller.
Controller connection
The controllers input/output uses 24V DC power (3A or over 3A) and the power can’t be
used for other electrical equipments. When the power is not connected and emergent stop
and limit position are both valid, the controller will in the state of emergent stop and limit
position.
The connection wire between the controller and the driver should be shielding wire.
Don’t plug in and plug out when power on.
Controllers input/output wire should connect well.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the MicroStep CC-S1 and is the answer not in the manual?

MicroStep CC-S1 Specifications

General IconGeneral
BrandMicroStep
ModelCC-S1
CategoryController
LanguageEnglish

Related product manuals